As a cryogenic liquid storage tank supplier, I’ve spent thousands of hours inspecting the vacuum jackets of the units we manufacture and service—because a vacuum leak in that jacket is the most common, and most critical, failure point for these tanks. Over 15 years in this industry, I’ve seen a small, unaddressed leak turn a properly insulated tank into an energy drain, or worse: cause internal pressure spikes that risk safety. Most of the time, those issues could have been caught with a consistent, hands-on inspection routine. Today, I’m breaking down exactly how we do it at our facility, so you can apply these steps to your own tanks—whether you’re operating our equipment or another brand’s, these principles apply. Cryogenic Liquid Storage Tank

First, let’s start with a quick refresh on what the vacuum jacket actually is. It’s the sealed, double-walled space between the inner shell (which holds liquid nitrogen, oxygen, argon, or other cryogens at -150°C to -269°C) and the outer shell of the tank. That vacuum is what prevents conductive and convective heat transfer from the ambient air (around 20°C, usually) into the cold inner shell. If there’s even a tiny pinhole leak, air or moisture seeps into the jacket, and the insulating performance drops fast. We’ve tested that: a vacuum level that drops from 1×10^-3 mbar (the threshold for a properly functional jacket) to 1×10^-2 mbar increases heat ingress by 10x. That means your liquid product vaporizes faster, leading to unnecessary refills, higher energy bills, and for many customers, lost product.
Before you even pick up a measurement tool, do a pre-inspection walkthrough—this is the step most people skip, and it’s where we’ve caught 20% of potential issues early. Start at the base of the tank, looking for any signs of physical damage: dents, scratches, or rust on the outer shell, especially around weld seams, valve connections, or the vacuum port (the small fitting where we pull the vacuum during manufacturing). A dent doesn’t always mean a leak, but a deep one at a weld can disrupt the seal. Next, check around all external connections: vacuum ports, relief valves, pressure gauges, and the piping that runs from the tank to your end use equipment. Even a loose fitting here can let air seep into the jacket over time. We once had a customer who missed a loose vacuum port cap; over six months, moisture seeped into the jacket, froze, and caused the outer shell to crack. That $50 cap would have prevented a $12,000 repair.
After the walkthrough, move on to non-destructive testing (NDT) methods—these are the core of a proper vacuum jacket inspection. The first and most accessible is the pressure rise test, which we use for all in-service tanks because it’s low-cost and reliable. Here’s how we do it correctly, not just the quick version you might find in a manual. First, make sure your tank is stable and the inner shell is at its normal operating pressure (not empty or at atmospheric pressure, because that will skew results). Then, isolate the vacuum jacket from the vacuum pump and any connected equipment, closing the valve between the jacket and the port. Seal the port tightly, and let the tank sit for 24 hours. Use a high-precision vacuum gauge (with a resolution of at least 1×10^-4 mbar) to measure the pressure at the start and end of the period. For a properly functioning jacket, the pressure rise should be less than 1×10^-3 mbar per day. If it’s higher than that, you have a leak—this test tells you a leak exists, but not where it is.
To locate that leak, we use two complementary methods: helium mass spectrometry leak detection, our go-to for all critical tanks, and thermal imaging, which is great for quick, on-site checks. Helium testing works because helium molecules are tiny—they pass through even micro-sized leaks that air won’t. First, evacuate the jacket to its normal operating vacuum level (1×10^-3 mbar or lower). Then, spray a 95% helium mixture (we use a calibrated spray wand) on every suspect surface: weld seams, fittings, dented areas, valve stems, and the jacket’s outer joints. The mass spectrometer is connected to the vacuum pump line, and when helium seeps into the jacket, the device will register a sharp spike—indicating a leak at that exact spot. We once used this on a 10,000-gallon liquid oxygen tank for a food processing plant; we found a pinhole leak at a weld on the top shell that the pressure test alone didn’t catch. That leak was letting in just enough moisture to cause ice buildup, which was slowly blocking the inner vent line. Catching it early prevented a 2-day shutdown of the plant’s cryogenic refrigeration system, which would have cost them over $20,000 in lost production.
Thermal imaging is a fast add-on for routine inspections, not a replacement for helium testing, but it’s perfect for checking thermal performance degradation. Here’s the right way to do it: on a clear, still day (wind or direct sun will skew your readings), use a thermal camera with a resolution of at least 320×240 pixels to scan the outer surface of the tank. A properly insulated vacuum jacket will have a uniform outer surface temperature, close to ambient air temperature. If you see a cold spot (10°C or lower than the surrounding area), that’s a sign heat is leaking through a damaged or degraded section of the jacket. We’ve found that cold spots often correlate to leaks within 1 foot of the area—just enough to narrow down where you need to do more precise testing. A few years back, a customer called us because their liquid nitrogen usage spiked 30% in a month; their thermal scan showed two cold spots on the outer shell. We did helium testing on those areas and found two small leaks that had formed at the base’s support welds, from years of vibration during transport. Fixing those brought their usage back to normal within a week.
Now, what about tanks that have been in service for 10+ years? The vacuum jacket’s performance doesn’t just drop from sudden leaks—it can degrade slowly over time, as residual moisture in the jacket outgasses, or the vacuum seal weakens from thermal cycling. That’s why we recommend a more in-depth inspection every 3 to 5 years for older tanks, versus annual checks for new ones. For those deep inspections, we also add a residual gas analysis (RGA) test, which measures the gases inside the vacuum jacket. If the RGA shows a high concentration of nitrogen (from air seepage) or water vapor, that tells you not just that there’s a leak, but how severe it is—and whether you need a full vacuum pull and jacket repair, or a partial fix. We recently serviced a 12-year-old argon tank for a semiconductor manufacturer; their RGA showed 80% nitrogen in the jacket, meaning 80% of the vacuum was gone. The pressure rise test only showed 5×10^-3 mbar per day, which is above the threshold, but the RGA confirmed it was a slow leak that had developed over time, not a sudden rupture. We repaired the small seal leak, re-evacuated the jacket, and brought the vacuum back to its original level, extending the tank’s life for another 10 years.
I want to be clear: there’s no “one-size-fits-all” for inspection frequency. Tanks in harsher environments—like outdoor tanks in coastal areas (where salt air accelerates corrosion) or tanks near heavy machinery (where vibration weakens seals)—need more frequent checks, twice a year at minimum. Tanks stored indoors in controlled temperatures can go 12 to 18 months between routine inspections. The key is to document every inspection: keep a log of pressure rise test results, thermal scan images, and helium test locations. That log lets you track changes over time—if your pressure rise jumps 0.5 mbar in a month, that’s a red flag, not a normal variation.
Now, a few common mistakes we see customers make that lead to missed issues. First, using uncalibrated tools for vacuum testing. A cheap vacuum gauge might be off by 10% or more, so you’ll misread a normal pressure rise as a leak. Second, rushing the pressure rise test—we’ve seen people cut it to 12 hours instead of 24, which is not enough time for a small leak to show a measurable difference. Third, forgetting to test the jacket’s “low points” and hard-to-reach areas, like the bottom of the tank or the back side of the outer shell. Those areas are prone to moisture buildup, corrosion, and hidden leaks that are easy to miss during a quick walkthrough.
If you’ve just done an inspection and found a leak, what’s next? Small leaks (less than 1×10^-8 mbar·L/s) can often be repaired with a vacuum port seal or a weld touch-up, but larger leaks or extensive jacket degradation usually require a full jacket re-evacuation, and sometimes, a section of the outer shell replaced. For in-service tanks, we always recommend having a professional with cryogenic equipment experience do the repair—working with low-pressure vacuum systems and cryogenic materials requires specific training to avoid safety hazards.

At our company, we don’t just manufacture and sell cryogenic storage tanks—we support them throughout their entire lifecycle, and that starts with rigorous inspections. Whether you’re managing a single tank at a small manufacturing facility or a fleet at a large research lab, regular, thorough inspections of the vacuum jacket will save you money on product costs, prevent unexpected downtime, and keep your operations safe. If you’re looking to implement a consistent inspection routine for your tanks, or if you need help troubleshooting a suspected vacuum jacket issue, our team is here to walk you through every step. We’re ready to discuss your specific storage needs, answer your questions, and help you keep your cryogenic equipment running smoothly.
Compressor And Expander References
- ASME Boiler and Pressure Vessel Code, Section VIII: Rules for Construction of Pressure Vessels, Division 1, 2023.
- Cryogenic Insulation Systems Handbook, National Institute of Standards and Technology (NIST), 2018.
- “Vacuum Leak Detection for Cryogenic Systems,” International Cryogenic Materials Conference Proceedings, 2021.
- ISO 14813:2018, Cryogenic Vessels – General Requirements for Vacuum Jacketed Storage Tanks.